  ecnr class rk5 250vac, 1 to 60a dual-element, time-delay fuses form no. ecnr 1-60 page 1 of 2 data sheet #1315 0509 bu-sb08624 catalog symbol: ecnr dual-element, time-delay C 10 seconds (minimum) at 500% rated current (8 seconds for fuses 30a or less) current-limiting volts: 250vac (or less) 125vdc (or less) amps: 1 to 60a ir: 200ka rms sym. agency information: ce, ul listed, std. 248-12, class rk-5, guide jddz, file e162363, csa certified, c22.2 no. 248.12, class 1422-02, file 700489 features ? provides motor overload, ground fault and short-circuit protection. ? helps protect motors against burnout from overloads. ? helps protect motors against burnout from single- phasing on three-phase systems. ? simplifies and improves blackout prevention (selective coordination). ? dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short-circuit and overload protection. ? the overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the amp rating of the fuse for a minimum of ten seconds. dimensions (inches) carton quantity and weight carton w eight per carton amp s quantity lbs kg 1C15 10 0.40 0.18 17.5C30 10 0.50 0.23 35C60 10 1.00 0.45 class rk5 fuse blocks (250v) catalog data (clip retaining spring standard, suffix r) t erminal t ype (suf fix no.) basic screw box lug 1 ? 4 " catalog w/ pres. w/ clip quick amp s number plate cu only connect 1 1 r25030-1 sr pr cr cor qr to 2 r25030-2 sr pr cr cor 30 3 r25030-3 sr pr cr cor 31 1 r25060-1 cr to 2 r25060-2 cr 60 3 r25060-3 cr catalog numbers (amps) ecnr1 ecnr7 ecnr17.5 ecnr45 ecnr2 ecnr8 ecnr20 ECNR50 ecnr3 ecnr9 ecnr25 ecnr60 ecnr4 ecnr10 ecnr30 ecnr5 ecnr12 ecnr35 ecnr6 ecnr15 ecnr40 poles
ecnr class rk5 250vac, 1 to 60a dual-element, time-delay fuses form no. ecnr 1-60 page 2 of 2 data sheet #1315 0509 bu-sb08624 current limitation curves time-current characteristic curvesC average melt time-current characteristic curvesC average melt the only controlled copy of this document is the electronic read-only version maintained by cooper bussmann. all other copies o f this document are by definition uncontrolled. this bulletin is intended to clearly present comprehensive product data and provide technical informat ion that will help the end user with design applications. cooper bussmann reserves the right, without notice, to change design or construction of any prod ucts and to discontinue or limit distribution of any products. cooper bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. once a product has been selected, it should be tested by the user in all possible applications. 8 10 15 30 60 fuse reducers for class r fuses equipment desired fuse catalog number fuse clip s (case) size (pairs) 250v 60a 30a no. 263-r 100a 30a no. 213-r 60a no. 216-r 200a 60a no. 226-r


▲Up To Search▲   

 
Price & Availability of ECNR50

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X